This publication, formerly known as UFC 2-000-05N and the P-80, provides facility planning criteria for use in computing quantitative facility requirements for Navy and Marine Corps installations. It includes planning criteria and data applicable to those categories of facilities to which a planning factor or data can be applied for computing facility requirements. Planning criteria contained in this publication are used in the preparation of Basic Facility Requirements, evaluation of existing assets, and the determination of specific facility requirements for shore facilities programs.

The Foreword and Chapter 1 include the authority and responsibilities of the Naval Facilities Engineering Command for the preparation and publication of planning criteria for use in calculating facility requirements at Navy and Marine Corps Installations and describe the use and applicability of the facility planning factors. The following sections contain a compilation of planning data and related space criteria developed by the Naval Facilities Engineering Command, furnished by systems commands, bureaus and offices of the Department of the Navy and issued by the Secretary of Defense.

 

Title

Date

View

CCR

FC 2-000-05N (Full Document)

05-16-2025

PDF

 

Title Page & Foreword

06-23-2023

PDF

CCR

Chapter 1 - Introduction

03-17-2023

PDF

CCR

Chapter 2 - Facility planning criteria for sections 100 through 900

100 Series - Operational and Training Facilities

04-04-2024

PDF

CCR

200 Series - Maintenance and Production Facilities

05-16-2025

PDF

CCR

300 Series - Research, Development, Test and Evaluation Facilities

03-02-2023

PDF

CCR

400 Series - Supply Facilities

05-30-2023

PDF

CCR

500 Series - Medical Facilities

03-17-2023

PDF

CCR

600 Series - Administrative Facilities
       Admin BFR Generator (MS Excel version)

03-02-2023
07-28-2022

PDF
xlsx

CCR

700 Series - Housing and Community Facilities

03-27-2025

PDF

CCR

800 Series - Utilities and Ground Improvements Facilities

03-31-2025

PDF

CCR

900 Series - Real Estate

02-06-2024

PDF

CCR

Appendix A - Category Codes for Navy and Marine Corps Real Property
Replacement for NAVFAC P72. Obtained from CCN module in Infads and reposted when new CCNs are uploaded.

06-27-2019

PDF

CCR

Appendix B - Units of Measure
Units of measure (UM) for Navy and Marine Corps real property category codes.

01-03-2013

PDF

CCR

Appendix C - Runway Capacity Handbook - Fixed Wing (formerly P-80.1)
Facility planning criteria for fixed wing aircraft runways at Navy and Marine Corps air installations.

06-01-1972

PDF

CCR

Appendix D - Naval Mobile Construction Battalion Facilities (formerly P-80.2)
Facility planning criteria for Naval Mobile Construction Battalion facilities.

04-01-2019

PDF

CCR

Appendix E - Airfield Safety Clearances (formerly P-80.3)
Airfield safety clearance criteria for Navy and Marine Corps air installations.

06-01-1982

PDF

CCR

Appendix F - Austere Facilities
Facility planning criteria for austere administrative, unaccompanied housing, dining, and fitness facilities at Navy shore installations.

03-17-2023

PDF

CCR