Status
Archive(s)
View/Download
Publish Date
Pages
64
Change Notice

Replaced by UFC 3-310-04

Series
3 - DISCIPLINE-SPECIFIC CRITERIA
3-300: STRUCTURAL AND SEISMIC DESIGN

The purpose of this document is to provide procedures for the assessment of the relative seismic vulnerability of a large inventory of buildings at a military installation. The structural systems of each building or groups of structurally similar buildings in the inventory are reviewed to obtain a numerical score. The scores obtained for all buildings or groups in the inventory are recorded in numerical order in an Installation Report to provide a numerical ranking of the seismic vulnerability of the buildings. This ranked list will provide a basis by which military installations can determine the order for performing seismic evaluations. Other building-specific aspects to consider in conjunction with this review should include: general condition, known site-specific seismic geologic hazards, occupancy type, number of occupants, year built, plans for future use, and availability of alternative buildings (redundancy of function).